Coaxial cable also called shielded cable, which is a
conductor to use a layer of shielding signal line structure. The outer shield
conductor is mainly used to reduce the signal line is coupled with the outside
world, including the coupling electric field (mutual capacitance) and magnetic
coupling (two coupling transformer). In addition, shielded conductors in the
textile network form a majority, after the cable shielding measures to
eliminate electric field. In general if there is no welding connection right
will greatly reduced the effect of shielding, because the signal line in the
welding point of not being completely covered with a shield conductor. In order
to eliminate the effect of mutual tolerance, our connection between the
connector and the cable shielding must be based on the 360 degree close
together.
In the terminal production, if can be shielded
conductors completely coated signal line, can eliminate the mutual capacitance
by the shield conductor can remove the electric coupling, there is no use for
magnetic field, magnetic power line signal line production can be easily
penetrating the light shield conductor, textile net, in order to reduce the
coupling effect of the magnetic field method the current transformer should try
to reduce the flow through the back road area, one without shielding the signal
line, the magnetic field coupling and the size of the electric current is
proportional to the area of road back; when we add our signal shielding
measures, or even do has single end grounding processing, however, we can see
back area road current no improvement; in the end we add shielding (into
coaxial cable), also has two end grounded do not, we can also find back to the
current road area has been significantly To reduce the order. So we can concluded
that the following three points: I without any shielding signal line is also
subject to interference of electric and magnetic coupling. I I shielding
measures and single ended ground signal lines (coaxial cables) can eliminate
electric field coupling, but there is still no way to solve the magnetic field
coupling. III installation of shielding and grounding of the two signal lines
(coaxial cable) can also eliminate the electric coupling and magnetic coupling.
Related Information
Why does the wire need electronic irradiation
2017-03-15High frequency wire test debugging to explain
2017-03-13Equipment line (AWM) UL2919 specifications
2017-03-10Equipment line (AWM) UL2725 specifications explanation
2017-03-08Equipment line (AWM) UL2547 specifications
2017-03-07Equipment line (AWM) UL2517 specifications explanation
2017-03-06Equipment line (AWM) UL2468 specifications
2017-03-03Equipment line (AWM) UL2464 specifications explanation
2017-03-02Equipment line (AWM) UL2095 specifications explanation
2017-03-01Equipment cable (AWM) UL1792 specifications
2017-02-28Equipment line (AWM) UL1533 specifications explanation
2017-02-27Equipment line (AWM) UL1365 specifications explanation
2017-02-24